For b,q in R^2 radians, alpha>0 radians and positive received power,
p=p0*g*exp(-2||q+b||^2/alpha^2) implies
z=log(p/p0)+2||q||^2/alpha^2 = V beta + Q h + rho + epsilon,
where Q has rows q_i^T/alpha, h=-4b/alpha, V contains the temporal basis, and the constant nuisance term absorbs -2||b||^2/alpha^2. There is no small-angle linearization in this algebra beyond the assumed Gaussian angular model.
Let P=I-UU^T for a thin orthonormal basis U of col(V). If V has full column rank, F=Q^T P Q is positive definite iff P Q has column rank two. Sufficiency: project, solve uniquely for h, then recover beta. Necessity: if P Q d=0 for a nonzero d, Q d lies in col(V), and a different nuisance beta absorbs it. This is a structural statement. A finite numerical eigenvalue cutoff detects weak conditioning but is not equivalent to the exact rank theorem.
Increasing nuisance degree can only remove information: if col(V1) is included in col(V2), Q^T P2 Q <= Q^T P1 Q in positive-semidefinite order. More samples do not fix a probe whose projected angular columns remain dependent.
With fixed exact angles, rho=0, and epsilon~N(0,sigma^2 I),
Cov(bhat)=alpha^2 sigma^2 F^-1/16.
The 95% ellipse uses squared Mahalanobis radius chi-square(2,.95)=5.991464547. A circumscribing Euclidean ball has radius
R95=alpha*sigma/4 * sqrt(5.991464547/lambda_min(F)) radians.
The scaling is dimensionally correct: Q,F,h,z are dimensionless and b is in radians. Replacing a valid known sigma by a larger random estimate does not shrink that known-sigma ball, but a residual estimate alone is not necessarily an upper bound on true noise. Conditioning on passing an acceptance rule does not preserve nominal coverage. Errors in Q invalidate the exact covariance; simultaneous power/angle noise and feedback are material here.
V4’s feasible GLS is explicitly an approximation, not an exact errors-in- variables maximum-likelihood estimator. For independent small encoder noise with per-axis variance sigma_q^2 and small relative power noise sigma_p^2, the transformed residual has first-order variance
s_i^2 ~= sigma_p^2 +16 sigma_q^2 ||q_i+b||^2/alpha^4.
Its second-order mean is approximately
4 sigma_q^2/alpha^2 - sigma_p^2/2 in two axes. The implementation subtracts
this mean, iterates weighted least squares, reports an approximate covariance,
and uses a chi-square whitened-residual test. These approximations are evaluated
empirically; neither their coverage nor their residual test is an exact theorem
under biased sensors, colored noise, fast gain changes or beam-width error.
For deterministic rho, bhat-b=-(alpha/4)(P Q)^+ P rho, hence
||bhat-b|| <= alpha ||P rho||/[4 sqrt(lambda_min(F))].
This is valid with exact angles and no additional noise. A remainder in col(V) is eliminated. A remainder Q d is indistinguishable from changing h and may produce zero residual with nonzero offset bias; V4 explicitly tests this counterexample. Fast fading is not made harmless by a polynomial basis.
For the eight rows [+x,-x,-x,+x,+y,-y,-y,+y] at equal dwell spacing, both
angular columns have zero zeroth and first temporal moments, and
F=4(a/alpha)^2 I. For any design energy E=||Q||_F^2,
lambda_min(Q^T P Q) <= trace(Q^T P Q)/2 <= E/2.
Equality requires isotropic information and P Q=Q. The specified quasi-static sequence meets both conditions. This is an elementary optimal-design equality, not a claim to have invented projection, balanced design, or dynamic actuator optimality. Dynamic trajectories and a sampling/holding policy require their own calculation.
At q0=0, exact current power pc, fixed b with ||b||<=B and a future lower log-gain slope -L, the old lower bound
pc*exp(-L*t-[4 B ||q||+2||q||^2]/alpha^2)
is valid for the actual q. V3 substitutes a noisy pc and a noiseless nominal q, and does not enforce the initial-state assumption. It therefore implements a surrogate, as its manuscript correctly acknowledges. Gaussian noise cannot support an unconditional deterministic measurement bound.
Use the actual current optical error e0=q0+b and actual delivered increment d=q(t)-q0. The exact ratio satisfies
log(p(t)/p(0)) = log(g(t)/g(0)) -2[2 e0^T d+||d||^2]/alpha^2.
The b^2 term cancels; no zero-initial-angle assumption is required. Suppose e0 lies in ball(c,R) and d lies in ball(dbar,r). Expanding d=dbar+v and using Cauchy-Schwarz gives the bound
Dbar=2 c^T dbar+2R||dbar||+||dbar||^2
+2(||c+dbar||+R)r+r^2.
Thus 2e0^T d+||d||^2 <= Dbar. Every term has units radians squared.
For c=0, the bound is sharp over these two balls:
Dmax=2R(||dbar||+r)+(||dbar||+r)^2.
Proof of sharpness: choose v collinear with dbar with length r and choose e0 in the same direction with length R. If dbar=0, choose any common direction. These choices attain the upper bound. This angular sharpness does not imply global tightness when optical gain, alpha and current power have additional coupled constraints.
For alpha>=alpha_min and log(g(t)/g(0))>=-L*t, a conservative power lower bound is
p_lower(t)=p_lower(0)*exp(-L*t-2 max(Dbar,0)/alpha_min^2).
Replacing a negative Dbar by zero avoids a sign error when bounding uncertain alpha. It deliberately forgoes a guaranteed pointing improvement. Positive power, a constant b and alpha over the window, and the delivered increment tube are indispensable hypotheses. If a scalar gain jump violates the slope model, the bound need not hold. The code checks actual lower-bound and tube violations after simulation using truth in the evaluator only.
There are N sampled times and five marginal standard Gaussian disturbances (two encoder, two rate, one relative power). Set
kappa=sqrt(2)*erfcinv(delta/(5N)).
Because Pr(|Z|>kappa)=delta/(5N), a union bound gives a single event E with Pr(E)>=1-delta on which all these disturbances are bounded over the whole mission. No independence across channels/times is needed for that union bound; correct Gaussian marginals and known scales are needed. For multiplicative power noise and eta=kappa*sigma_p<1,
pm/(1+eta) <= ptrue <= pm/(1-eta) on E.
These simultaneous intervals remain valid at a start time selected from the same observations. A pointwise 99% interval evaluated at an adaptively chosen trigger would not establish this mission-wide statement.
Acquisition is enabled only if the upper bound is below receiver sensitivity. If the interval straddles sensitivity, the working-link budget is retained. Consequently the probability of any falsely enabled acquisition mode is at most delta under E’s model and the stated horizon, including adaptive trigger times. This does not assert diagnosis success or bound outages outside a certified probe window.
V4 includes the six finite parameter models given by J/J0 in {0.8,1,1.25}
and tau/tau0 in {1,1.5}. It does not interpolate this into a continuous robust
parameter interval. The nominal PID controller remains fixed when true inertia
or lag changes. One-axis unsaturated state is [q,v,a,I]. The exact A,B matrices
and their RK4 polynomial map are in pid_discrete.m; the input comprises
reference, encoder error and rate error.
For each parameter member, the effect of all past bounded sensor inputs at a sample is enclosed by the finite impulse sum
r_x <= sum_{j=0}^{N-1} |Ad^j Bd_noise| w_max.
For torque and rate constraints at RK4 intermediate stages, V4 uses the exact stage H,J matrices and their impulse sums, retaining cross-state cancellation before taking absolute values. If the enclosure permits a torque or rate clamp, the candidate receives no linear-model certificate. Otherwise induction shows that the unsaturated discrete map agrees with the clipped simulator at every stage, so the calculated tube encloses all noise realizations on E for that finite model set. Floating-point roundoff is not formally enclosed.
The candidate tube encloses deviations from the nominal candidate mean. The current measured angle adds its own sqrt(2)kappasigma_q radius when expressing delivered increments relative to the measured current angle. Before the first probe the reference is zero, as assumed by the predictor. A future retry after a nonzero correction would require a predictor initialized from its complete reference history; the present method allows one attempt only.
For each candidate, C=sum dt*1{p_lower<pmin}. Under all hypotheses and on E, sampled actual outage during the candidate is <=C. Selection with C<=budget therefore gives a mission-event conditional sampled-outage certificate. It is not a continuous-time certificate, a floating-point proof, a guarantee for arbitrary actuator parameters, or a safety result after the probe ends. A zero-budget probe cannot create a sampled outage on E if the tube and optical premises hold. Those assumptions must not be elided from the manuscript.
The objective is duration seconds plus 0.03 per urad^2 times angular energy urad^2*s, yielding seconds. Library search is exact over the declared candidates only. A first-order predicted statistical radius checks diagnostic feasibility; it is not a robust lower information certificate for all uncertain motions. Actual measured-angle rank and fit uncertainty are checked again after probing. One can derive sigma_min(P Q_actual)>=max(0,sigma_min(P Q_nom)-||Delta Q||_F), but that bound is often vacuous and is not misrepresented as an operative guarantee. Safe-to-attempt does not mean guaranteed-to-diagnose.
The online bound/search cost is O(KH) and stored candidate trajectories O(KH), for K candidates and H samples. Offline finite-model tube construction is O(K M N) small-matrix operations. Feasible GLS with p<=5 coefficients takes O(I N p^2+p^3) and O(Np) workspace. RK4 simulation cost is separate from online planner/estimator timing. Runtime and retained buffer size are measured, not claimed as embedded worst-case execution time or process peak memory.