What was actually verified

The optical kernel is a displaced far-field Gaussian intensity sampled by a small circular receiver. Its divergence parameter is the angular 1/e^2 intensity radius, not an unspecified full-angle divergence. With L=800km and alpha=20urad, beam radius is 16m; receiver radius is 0.05m, giving a/w=0.003125. Nominal captured power is 3.9062uW for 0.5W optical power and efficiency 0.4.

An independent disk-aperture quadrature evaluates

P=Pt*eta*(4/w^2)*exp(-2d^2/w^2)*integral_0^a r exp(-2r^2/w^2) I0(4rd/w^2) dr

at 20 offsets from zero to 60urad. Its maximum relative disagreement with the retained approximation is 1.7576e-4. This validates the numerical optical approximation in this geometry, not its correspondence to a physical terminal.

The independently constructed linear sampled-PID state map matches the imported RK4 derivative implementation under unsaturated conditions for the six declared actuator models. The old deterministic half-step check gives an angle change of about 2.17e-13rad. The sensitivity half-step experiment additionally changes sampling/noise/feedback and therefore does not isolate numerical integration.

Parameter evidence and limitations

Quantity Evidence status Consequence
Gaussian angular power law Consistent analytical model; numerical aperture approximation checked Not verified against a measured beam profile
800km range, 0.10m receiver Inherited scenario assumptions No orbit/range dynamics, receiver attitude or obstruction model
20urad divergence Declared 1/e^2 half-angle; plausible optical scale, not hardware calibrated Published divergence definitions must be converted before comparison
0.5W and efficiency0.4 Inherited optical-budget assumptions Not measured electrical consumption; no wall-plug energy claim
J=.002kg m^2, tau=.08s, torque2uNm Numerical gimbal/controller surrogate from supplied source No identified mirror/gimbal hardware with these simultaneous parameters
Encoder sigma=.08urad, rate sigma=.16urad/s Assumed independent Gaussian scales Not sensor specifications; no validated rare-tail or bias model
Relative power sigma=.008 Assumed multiplicative sensor error No photon-counting/background/ADC/shot-noise calibration
Sensitivity1.5uW Binary receiver abstraction No measured BER, coding, background, wavelength or sensitivity curve
Gain slope/curvature Prespecified test disturbances No thermal/laser calibration or on-orbit probability distribution
Finite six-member actuator set Explicit discrete hypotheses Does not enclose a continuous uncertain hardware parameter interval

NASA’s current communications survey and the actuator review establish hardware context and diversity, not calibration of these exact values. For example, published total terminal electrical powers cannot be substituted for the model’s optical transmit power. The source has no specified wavelength or transmitter waist, so a complete diffraction/link budget cannot be reconstructed.

Minimal independent optical-bench study

No optical hardware, external telemetry or laboratory acquisition connection is available in this environment. The following is an executable experimental design for a laboratory, not a claim that measurements have been collected.

  1. Use an existing characterized Gaussian optical source, two-axis steering or translation stage with an independently calibrated position reference, a variable attenuator, and a scalar receive-power detector. A reference detector may measure injected attenuation for evaluation, but must not be provided to the diagnostic algorithm if scalar-only comparisons are intended.
  2. Measure beam shape and the relationship between stage angle/translation and received intensity. Choose a receiver sampling aperture or fiber arrangement appropriate to that beam. Match dimensionless displacement q/alpha rather than claiming the laboratory literally reproduces an 800km link. If fiber coupling changes the observation law, derive and test that law explicitly.
  3. Record dark response, power noise, encoder bias, rate noise, drift, saturation, time synchronization and complete actuator transients using independent calibration data. Check autocorrelation and tails. A short Gaussian-looking calibration record cannot validate mission-wide rare-tail bounds of order delta/(5N); use defensible hardware bounds or a separately justified statistical envelope instead of importing the simulated Gaussian claim.
  4. Declare a real receiver-quality/service threshold from a calibrated link measurement, or explicitly label an imposed power threshold as a surrogate. Freeze the noise/beam/actuator sets and confidence levels before validation.
  5. Apply randomized pointing offsets and independent attenuation ramps under held-out run identifiers. Match reference schedules, sensing budgets and limits for all algorithms. Log independent truth only to the evaluation side.
  6. Include near-threshold healthy links, biased sensing, partial occlusion, abrupt faults during probing, continuous actuator uncertainty and loss of aligned optical budget. Report all exclusions and instrument failures.
  7. Compare predicted lower power with measured power using a calibrated measurement-uncertainty allowance. Report certificate applicability and violations separately from estimator accuracy and recovery. Do not silently remove trials whose hypotheses fail; distinguish those failures explicitly.

At least one independently identified actuator must replace the finite-model assumption before claiming a hardware service guarantee. A continuous-parameter reachability enclosure and an online change-of-fault monitor are additional research requirements. A hardware-in-the-loop run of the same unvalidated optical equation would check timing/interfaces, not independently validate that optical model.